Files
peerspeak/docs
molluskandClaude Opus 5 297f4397a7 docs: phase 5 dry-run audit results — GATE FAILED, two findings
Impl plan §5's required results file. Phase 6 does not start.

F1 (fatal): the PipeWire registry `global` event delivers only a filtered
subset of node properties, and eight of the properties the phase-3 adapter
reads are not among them — peerspeak.owned, pulse.module.id, node.link-group,
application.process.id, node.passthrough, device.api, factory.name,
alsa.driver_name (plus port.exclusive on Ports). They are silently absent, so
the primary taint root never fires, the AEC identity can never validate, and
session_device is universally false. Measured on PipeWire 1.6.8 /
WirePlumber 0.5.15, with the full announced key set for all five object types
recorded. Links and Clients are unaffected; pulse-PID derivation works.

F2: with F1 in force no node has a strong owner key, so any tainted capture
stream is an unbounded tainted reader and phase 2's fail-closed backstop
excludes every Stream/Output/Audio on the machine. Fail-closed, so silence
rather than echo — but entirely non-functional, and non-functional in a way an
exclusion-only checklist would have scored as passing. The eligible half of
the §5.1 partition is what caught it, exactly as the plan argued it would.

The fix direction is measured and recorded: binding each Node and reading its
info props recovers every missing property, which is the pattern phase 3
already built for Links. factory.id is not a shortcut — it resolves to
"adapter", not api.alsa.pcm.sink.

O5 is closed with ~4 orders of magnitude of headroom: 308 graph events in
6.5s under churn, every recompute under 50us (max 15us), busy fraction 0.0004.
Caveat recorded — measured on the degraded graph, and the F1 fix adds
per-node bind I/O this run did not measure.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-07-25 15:43:23 -04:00
..